Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Pусский |
| No.3581540
| No.3581540
- Product Categories
- Friendly Links
- home > Supply > The Supply FLUKE773 mA level process clamp meter, Fluke773CHN mA Process Clamp table
| Information Name: | The Supply FLUKE773 mA level process clamp meter, Fluke773CHN mA Process Clamp table |
| Published: | 2012-03-08 |
| Validity: | 50000 |
| Specifications: | Category FLUKE773 mA Process Clamp Meter, Fluke773CHN mA Process Clamp Table |
| Quantity: | 1.00 |
| Price Description: | |
| Detailed Product Description: | Category FLUKE773 mA Process Clamp Meter, Fluke773CHN mA Process Clamp Table Contact: Zou Pengcheng; 443 813 032 Tel. :13144813660,0755 -36,890,859 U.S. the Fluke FLUKE773 mA level process clamp meter, Fluke773CHN mA Process Clamp table features: (circuit troubleshooting) ? no need to disconnect the circuit, can be measured 4 to 20mA signal ? Output 4 to 20mA current signal ? 24V DC voltage circuit power supply Available tables pen series to measure mA current ? stepper output mA signal to a linear ramp or 25% Can activate the HART loop 250Ω series resistance ? Power saving function, auto-shutdown, the backlight time control functions, extended battery life Category FLUKE773 mA Process Clamp Meter, Fluke773CHN mA Process Clamp Table Contact: Zou Pengcheng; 443 813 032 Tel. :13144813660,0755 -36,890,859 Category FLUKE773 mA process clamp meter the U.S. Flow g Fluke773CHN, mA Process Clamp table unique characteristics (circuit troubleshooting advanced features): ? mA output / measurement functions to facilitate the adjustment of the valves or mA isolator / troubleshooting. MA input signal and to provide for the device under test and measuring the signal of 4 to 20mA output (or feedback) ? jaw measuring mA continuous output function. With the use of paperless recorder or the Fluke 289, in the case of continuous open-loop monitoring and records will be able 4 to 20mA signal to help exclude loop fault ? Measure 0-30 V DC voltage ? Output 1-5 V or 0-10 V DC voltage signal Linear ramp or 25% step output voltage signal Contact: Zou Pengcheng; 443 813 032 Tel. :13144813660,0755 -36,890,859 The Category FLUKE773 mA Process Clamp Meter, Fluke773CHN mA level process clamp meter functions: FLUKE771 FLUKE772 FLUKE773 The positioning of non-contact mA loop measurement of the integrated mA loop troubleshooting process troubleshooting MA measurement, non-break X X X MA measurement, access type X X Loop power supply X X MA output X-X- DC voltage measuring X- DC voltage output X MA proportional output X Synchronization mA measurement and output X Contact: Zou Pengcheng; 443 813 032 Tel. :13144813660,0755 -36,890,859 FLUKE773 mA level process clamp meter, Fluke773CHN mA Process Clamp table function parameters: Earth's magnetic field affect <0.20 mA Battery (4) 1.5 V Alkaline, IEC LR6 Working hours of 12 mA source, 500 ohm, 12 hours Size (HxWxL): 772, 773: 41.3 mm x 76 mm x 248 mm (1.625 in. x 3 in. x 9.75 in.) 771: 59 mm x 38 mm x 212 mm (2.32 in. x 1.5 in. x 8.35 in.) 772, 773 Weight: 415 g (14 oz) 771: 260 g (9.1 oz) Operating temperature -10 ° C to 50 ° C Storage temperature -25 ° C to 60 ° C Operating Humidity <90% @ <30 ° C; <75% @ 30 ~ 55 ℃ Working altitude of ~ 2,000 m Storage elevation height IP rating IP 40 Random 2 g shock, 5 Hz to 500 Hz 1 m drop test drop test (not including the jaw) EMI, RFI, EMC meet EN61326-1 requirements. Note: jaw measuring current for 1 V / m to 3 V / m the EMC field strength measurement results automatically add 1mA. Temperature coefficient when the temperature of 28 ℃, 0.1 (/ ℃ x provides accuracy) Warranty period, electronic devices for three years, the jaw assembly and the cable for one year Category FLUKE773 mA Process Clamp Meter, Fluke773CHN mA Process Clamp Table Contact: Zou Pengcheng; 443 813 032 Tel. :13144813660,0755 -36,890,859 Scene valve adjustment / troubleshooting is a good helper Customers in the adjustment of the valve, commonly used tuning for two maintenance personnel at the scene by using the signal source (manual operator) with a multimeter, continue to test and compare the measurement results, record data. Therefore, the adjustment of a valve is very cumbersome, especially the small opening when repeated checksum. Use F773 CHN, to quickly distinguish between the failure of electrical failure or mechanical failure. Save time, rapid investigation, personnel savings, cost savings, and a person and a table to complete the valve calibration. Category FLUKE773 mA Process Clamp Meter, Fluke773CHN mA Process Clamp Table A good helper robot troubleshooting Automated production line robot failure is difficult to troubleshoot, and sometimes control the robot action, 4-20mA signal will be triggered by interference from other signal or external signal, resulting in the robot burned or abnormal movements, but engineers do not seize and The analysis led to the source and timing of this problem occurring. With the F773, they can easily seize the culprit. Coupled with a similar 289 or signal recorder (can be received 773 timely mA signal output) can be achieved for a long time to monitor and capture mA loop accidental / suspicious / unusual event to help determine suspicious / abnormal mA signal source and time of occurrence. FLUKE773 mA level process clamp meter, the Fluke 773CHN mA level Process Clamp Meters Contact: Zou Pengcheng telephone :13144813660,0755-36,890,859 QQ; 443 813 032 |
Admin>>>
You are the 9109 visitor
Copyright © GuangDong ICP No. 10089450, Shenzhen Sea Technology Industry Development Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 9109 visitor
Copyright © GuangDong ICP No. 10089450, Shenzhen Sea Technology Industry Development Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility

